Vapor-heated conducting oil circulation reactor
Principal technical data of conducting oil circulation heated reactor, vapor-heated carbon reactor and vapor-heated stainless steel reactor
Reactor specification L |
Diameter of inner core
Ø MM |
Jacket diameter
Ømm |
Motor power KW |
Reducer model number |
Agitator speed r.p.m |
30 |
400 |
500 |
0.6-1.1 |
M2 |
60-80 |
50 |
500 |
600 |
0.6-1.1 |
M3 |
60-80 |
100 |
550 |
650 |
1.1-1.5 |
M4 |
60-80 |
150 |
600 |
700 |
2.2 |
M6 |
60-80 |
200 |
650 |
750 |
2.2 |
M6 |
60-80 |
300 |
800 |
900 |
2.2 |
M6 |
60-80 |
500 |
900 |
1000 |
2.2 |
M6 |
60-80 |
800 |
1100 |
1200 |
4 |
M8 |
60-80 |
1000 |
1200 |
1300 |
4 |
M8 |
60-80 |
1500 |
1300 |
1400 |
4 |
M8 |
60-80 |
2000 |
1400 |
1500 |
4 |
M8 |
60-80 |
2500 |
1400 |
1500 |
7.5 |
BLB7.5-4-13 |
90 |
3000 |
1400 |
1500 |
7.5 |
BLB7.5-4-13 |
90 |
3500 |
1400 |
1500 |
7.5 |
BLB7.5-4-13 |
90 |
4000 |
1500 |
1600 |
7.5 |
BLB7.5-4-23 |
63 |
5000 |
1600 |
1700 |
7.5 |
BLB7.5-4-23 |
63 |
6000 |
1800 |
1900 |
15 |
BLB15-5-13 |
100 |
8000 |
2000 |
2100 |
15 |
BLB15-5-13 |
100 |
32000 |
3000 |
3200 |
37 |
BLB450-11-45 |
50-100 |
Other special specifications can be designed separately
Conducting oil circulation heating is suitable for reactors and equipment whose capacities are above 500L.
Please mark the maximum working pressure, working temperature and working medium when ordering these equipment. |