¡¡ ProductHeat Exchanger Serial Plate coil heat exchanger
¡¡
Plate coil heat exchanger
 

Plate coil heat exchanger

The plate coil heat exchanger is a kind of high-efficient heat exchanging equipment, and it is suitable for vapor-to- vapor, vapor-to-liquid, and vapor-to-vapor heat transfer. It is adoptable for chemical, petroleum, solvent, pharmaceuticals, food, light-industry, textile, metallurgical, steel rolling, and coal carbonization coking industries. According to different structure styles, the plate coil heat exchangers can be divided into nondetachable plate coil heat exchanger (I model) and detachable plate coil heat exchanger (II, III model).



structure and performance

1. The equipment is made by wrapping two plates to form two uniform spiral channels. Two kinds of heat transfer media perform total counter flow, which greatly enhances heat-exchanging effect. Consequently, an ideal heat exchanging effect can be obtained even if the temperature difference of two kinds of media is small.
2. The connection tubes on the housing adopt tangential structure with small local resistance. Since the curvature of the spiral channels is uniform, the liquid will not turn abruptly when flowing in the equipment, and therefore the small total resistance will improve the designed flow rate to increase its heat transfer capacity.
3. The spiral channel end plane of I model nondetachable plate coil heat exchanger uses weld sealing to ensure a better tightness.
4. Basically speaking, the structure of II model detachable plate coil heat exchanger is almost the same to that of the nondetachable plate coil heat exchanger. However, one of the channels can be taken apart for cleaning. So, it is suitable for heat exchange of viscous or precipitated liquid.
5.The structure of III model detachable plate coil heat exchanger is almost the same to that of the nondetachable plate coil heat exchanger. However, both of the channels can be taken apart for cleaning. And it gains extensive applicable scope.
6. The plate coil heat exchangers consist of PN0.6, 1.0,1.6,2.5Mpa serial per nominal pressure (endurable maximum working pressure of single channel).
7. When single equipment cannot satisfy operating requirements, the combination of multiple equipments is permissible. While the combination should abide by the following specifications:
The spacing intervals between equipment and channels should be the same in parallel or series combination; when it comes to hybrid combination, it means one parallel channel and one series channel.


Some heat exchangers are listed as following:

PN0.6, 1.6Mpa nondetachable (I model) plate coil heat exchanger made of stainless acid resistant steel

Nominal heat transfer area m2 Spacing intervals between channels mm Calculated heat transfer area m2 Handing capacity at 1m/ces flow rate m3/h Nominal diameter of connection tube dg Model Weight (kg)
I 6B I 6B
1 6 1.0 3.89 40 I 6£¬I 16B1-0.2/300-6 44 50
2 6 2.1 3.89 40 I 6, I 16B2-0.2/400-6 78 85
4 6 4.4 8.2 50 I 6, I 16B4-0.4/400-6 131 135
10 4.5 17.3 80 I 6, I 16B4-0.5/450-10 129 133
10 4.8 13.7 70 I 6, I 16B4-0.4/500-10 161 205
8 6 7.3 8.21 50 I 6, I 16B8-0.4/500-6 212 215
10 7.85 17.3 80 I 6, I 16B8-0.5/550-10 235 273
10 7.3 20.90 80 I 6, I 16B8-0.6/500-10 237 275
10

6

11.1 8.21 50 I 6, I 16B10-0.4/600-6 295 355
10 11.5 17.3 80 I 6, I 16B10-0.5/650-10 315 405
10 11.2 20.90 80 I 6, I 16B10-0.6/600-10 305 395
15 6 16.9 12.54 70 I 6, I 16B15-0.6/600-6 415 490
10 14.72 17.3 80 I 6, I 16B15-0.5/760-10 405 575
10 15.0 28.1 80 I 6, I 16B15-0.8/600-10 400 570
14 15.6 39.3 100 I 6, I 16B15-0.8/700-14 505 680
20 6 21.7 8.21 50 I 6, I 16B20-0.4/800-6 540 710
10 21.0 20.90 80 I 6, I 16B20-0.6/800-10 555 735
14 20.9 39.30 100 I 6, I 16B20-0.8/800-14 660 830
25 10 26.6 29.90 100 I 6, I 16B25-0.6/900-10 610 950
14 26.9 39.20 100 I 6, I 16B25-0.8/900-14 720 1060
30 10 28.2 28.10 100 I 6, I 16B30-0.8/800-14 750 1180
14 32.2 39.20 100 I 6, I 16B30-0.8/1000-14 980 1370
40 10 45.4 35.30 100 I 6, I 16B40-1.0/900-10 1130 1515
14 40.2 19.4 125 I 6, I 16B40-1.0/1000-14 1200 1630
50 10 53.9 35.3 100 I 6, I 16B50-1.0/1000-14 1360 1755
60 10 61.05 35.3 100 I 6, I 16B60-1.0/1100-10 1920 2112
14 60.08 49.40 125 I 6, I 16B60-1.0/1200-14 2000 2200
80 10 81.83 35.3 100 I 6, I 16B80-1.0/1200-10 2560 2816
14 80.9 49.40 125 I 6, I 16B80-1.0/1400-14 2667 1934
100 10 101.9 35.3 100 I 6, I 16B100-1.0/1300-10 3200 3520
14 100.06 49.40 125 I 6, I 16B100-1.0/1500-14 3333 3666
120 10 115.5 35.3 100 I 6, I 16B120-1.0/1500-10 3870 4257
14 119.0 49.4 125 I 6, I 16B120-1.0/1700-14 4020 4422
130 14 128.80 49.4 125 I 6, I 16B130-1.0/1750-14 4241 4665
18 129.09 63.5 150 I 6, I 16B130-1.0/1967-18 4462 4908
150 14

148.1

49.4 125 I 6, I 16B150-1.0/1890-14 4702 5172
18 148.2 63.5 150 I 6, I 16B150-1.0/2010-18 4962 5458

Pg6, 16 nondetachable (I model) plate coil heat exchanger made of carbon steel

Nominal heat transfer area m2 Spacing intervals between channels mm Calculated heat transfer area m2 Handing capacity at 1m/ces flow rate m3/h Nominal diameter of connection tube dg Model
Weight(kg)

I 6T

I 16T

6 6 6.5 8.2 50 I 6, I 16T6-0.4/500-6 230 280
10 5.8 13.7 70 I 6, I 16T6-0.4/600-10 285 350
8 6 8.7 8.2 50 I 6, I 16T8-0.4/600-6 370 430
10 7.7 17.3 80 I 6, I 16T8-0.5/660-10 395 454
10 8.7 13.7 70 I 6, I 16T8-0.4/700-10 405 465
10 6 9.9 12.5 70 I 6, I 16T10-0.6/500-6 335 395
10 9.2 17.30 80 I 6, I 16T10-0.5/660-10 472 543
10

8.8

20.9 80 I 6, I 16T10-0.6/600-10 410 495
15 6 12.5 8.2 50 I 6, I 16T15-0.4/700-6 510 580
10 14.64 17.30 80 I 6, I 16T15-0.5/800-10 679 781
10 13.3 20.9 80 I 6, I 16T15-0.6/700-10 575 680
14 13.8 29.2 100 I 6, I 16T15-0.6/800-14 640 755
20 6 19.0 12.5 70 I 6, I 16T20-0.6/700-6 730 845
10 18.3 28.1 80 I 6, I 16T20-0.8/800-10 735 870
14 18.5 39.3 100 I 6, I 16T20-0.8/800-14 810 960
25 10 23.1 28.1 100 I 6, I 16T25-0.8/800-10 935 1120
14 23.3 49.4 125 I 6, I 16T25-1.0/800-14 1000 1165
30 10 29.0 35.3 100 I 6, I 16T30-1.0/800-10 1190 1470
14 28.1 59.4 125 I 6, I 16T30-1.2/800-14 1170 1425
40 10 40.9 20.9 80 I 6, I 16T40-0.6/1200-10 1725 1885
14 42.3 39.3 100 I 6, I 16T40-0.8/1200-14 1845 2110
18 44.9 63.5 150 I 6, I 16T40-1.0/1200-18 2075 2405
50 10 46.2 35.5 100 I 6, I 16T50-1.0/1000-10 1800 2085
14 53.2 49.4 125 I 6, I 16T50-1.0/1200-14 2490 2595
18 54.0 76.3 150 I 6, I 16T50-1.2/1200-18 2435 2820
60 10 56.8 20.9 80 I 6, I 16T60-0.6/1400-10 2330 2635
14 60.7 39.3 100 I 6, I 16T60-0.8/1400-14 2595 2850
18 59.6 63.5 150 I 6, I 16T60-1.0/1400-18 2730 3150
80 10 76.4 28.1 100 I 6, I 16T80-0.8/1400-10 2970 4060
14 78.6 39.3 100 I 6, I 16T80-0.8/1600-14 3210 3605
18 82.0 63.5 150 I 6, I 16T80-1.0/1600-18 3580 4205
100 10 101.4 28.1 100 I 6, I 16T100-0.8/1600-10 3905 4330
14 98.8 49.4 125 I 6, I 16T100-1.0/1600-14 4040 4585
18 98.8 76.3 150 I 6, I 16T100-1.2/1600-18 4200 4930
120 10 115.5 42.5 125 I 6, I 16T120-1.2/1400-10 4350 4980
14 119.0 59.4 125 I 6, I 16T120-1.2/1600-14 4770 5440
150 14 149.15 59.4 125 I 6, I 16T150-1.2/1800-14 6431 7396
18 149.86 76.3 150 I 6, I 16T150-1.2/2000-18 6643 7639
20 147.6 83.81 150 I 6, I 16T150-1.2/2050-20 6769 7784
¡¡
¡¡ ¡¡
¡üBack¡¡¡¡¡¡¡¡¡ýNext¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡